Carbon fiber heating wire
Insulating materials: Silicone rubber
Temperature: 200 degrees celsius limit
Heating conductor: 6K
Conductor resistance: 66±10% Ω / M
High voltage test: 3000V
Leakage current: 0.05mA/m
The product can withstand the power of power: 20W/M
Diameter: 2.5±0.2 MM
Infrared wavelength: 8UM-18UM
How to Calculate Power?
Voltage*Voltage÷resistance=electric power
For example,
using 5m 6K carbon fiber cable on 110V, the power is:
110V*110V÷(5meters*66Ω)=33.9W(6.7w/m)
using 10m 6K carbon fiber cable on 220V, the power is:
220V*220V÷(10meters*66Ω)=73W(7.3w/m)
Temperature:
The power of the cable is based on the length that you use, you can calculate the power according to above examples.
Power = 5W/m, the temperature is about 30~40C degrees;
Power = 10W/m, the temperature is about 40~50C degrees;
Power = 15W/m, the temperature is about 50~60C degrees;
Power = 20W/m, the temperature is about 60~70C degrees;
Please notice that this is for your reference, not exactly right because of different test conditions.
Thermostat
The thermostat is suitable for the temperature control of floor heating cables or heating films, which can keep the room at a suitable temperature and meet the requirements of a safe, energy-saving and comfortable environment
Warning:
Please do not rotate the control knob since the factory default has been calibrated !
Specification:
Voltage: 220~240VAC 50/60Hz
Power consumption: 5VA
Temperature control range: 5~40℃
Temperature limit range: 25~55℃
Power save mode temperature: 5℃
Temperature deviation: ±0.5K
Ambient temperature: -5~50℃
Degree of protection provided by enclosure: IP20
Outer sensor: Length of cable: 3M
Package Includes:
50m 6K heating cable + 10 pcs copper tube + 10 pcs sleeves
1 pc of thermostat